Mail Us :
aquadeepwatersolutions@gmail.com
Call Us :
+91 7838384238
GST Number: 09BGTPD4141F1ZE
+91 8130315248
Call Now : +91 8130315248
Home
About
Products
Commercial RO Plant
Industrial RO Plant
Softener
ETP
Product Services
Plant
250 LPH Plant
500 LPH Plant
1000 LPH Plant
2000 LPH Plant
privacy & policy
Enquiry
Contact
Product 250 LPH
SL.NO.
PRODUCT DESCRIPTION
Description
Features
1.
250 lph
Flow Rate : 250 lph
Capacity Utilization: 91-95% INPUTS
2.
250 lph
Total Dissolved Solids Input: : < 3000PPM
OUTPUT (Treated Water Quality) From RO Plant : < 50 PPM
SL.NO.
RAW WATER PUMP
Purpose
Specifications
3.
Flow Rate : 250 lph
To feed the Dual Media Filter at pressure more than 2.0 bar, which is min. operating pressure for filter.
MOC :
CRI
Type :
Horizontal Centrifugal
Power Required:
1 0.5 Hp
Electrical :
230 V, Single phase , 50 hz
SL.NO.
HIGH PRESSURE PUMP
Purpose
Specifications
4.
Flow Rate : 250 lph
To feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate,
flow and recovery.
MOC :
Stainless Steel
Type :
Vertical Multistage
Power Required:
1.5 HP
Electrical :
230 V, Single phase,50 hz
Make:
CRI/LUBI/KIRLOSKAR
SL.NO.
MICRON FILTER
Purpose
Specifications
Housing
Cartridge
5.
Flow Rate : 250 lph
To remove the fine particles up to 05 microns and reduce silt density index levels to acceptable level.
Cartridge Filter & Housing
MOC of Housing:
PP
Length :
20”
Diameter:
6
Quantity :
1 No.
Cartridge MOC :
Polypropylene
Length:
20”
Diameter :
4.5”
Quantity :
1 No.
Micron rating:
05 micron
SL.NO.
VESSEL (SAND FILTER + ACTIVTED CARBON FILTER )
Purpose
Specifications
6.
Flow Rate : 250 lph
To remove the total suspended solids, dirt , iron and reduce silt density index which can foul the membranes.
Make:
Alpha, Pentair
Type :
Material of Construction:
FRP
Diameter:
10
Height :
54
Testing Pressure
15 kg/cm2
Opening :
Top
Opening :
Top
Valve :
¾”
Quantity :
1 No.
SL.NO.
HIGH PRESSURE PUMP
Purpose
Specifications
7.
Flow Rate : 250 lph
To remove the total suspended solids, dirt , iron and reduce silt density index which can foul the membranes.
MOC :
Stainless Steel:
Type :
Vertical Multistage
FRP
Power Required:
1.5 HP
Electrical:
230 V , Single phase, 50 hz
Make:
CRI/LUBI/KIRLOSKAR
SL.NO.
RO MEMBRANE
Purpose
Specifications
8.
Flow Rate : 250 lph
To remove the major part of TDS up to 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow andrecovery.
Type:
Spiral Wounded
Diameter of Membrane:
4.0 inch
Length of Membranes:
40inch.
No. of Membranes :
1
Make of Membranes: by default hii-flow (other brand we can use on demand by customers. it we be extra chargable. price depend on brand)
Salt Rejection per Membrane: 98-99%
System Recovery: 95%
SL.NO.
ELECTRICAL PANAL
Purpose
Specifications
9.
Flow Rate : 250 lph
A control panel is provided as a safety measure for the pumps & other electrical items
Complete Starters, Overload relays, and single- phase preventer for Pump.
AUTOMATIC
SL.NO.
INSTRUMENTATION
Purpose
Purpose
10.
Flow Rate : 250 lph
Flow Meter :
To measure the online flow of water
High Pressure Switch :
To protect RO pump from back pressure
Low Pressure Switch :
To protect RO pump from dry running
Pressure Gauges :
For calculate Pressure for each unit in RO system
SL.NO.
PLUMBING & FITTINGS
Purpose
Specifications
11.
Flow Rate : 250 lph
Valves, pipelines RO module is in upvc Astral.
The System will be on common SS base frame