Product 500 LPH

SL.NO. BASIS OF DESIGN AND CAPACITY Flow Rate Capacity Utilization: Total Dissolved Solids Input: OUTPUT (Treated Water Quality) From RO Plant :
1. 500 Liter Per Hour 500 LPH 91-95% INPUTS
(Wastewater Quality) To RO Plant:
< 3000PPM < 50 PPM
SL.NO. RAW WATER PUMP Purpose Specifications
2. Flow Rate : 500 lph To feed the Dual Media Filter at pressure more than 2.0 bar, which is min.
operating pressure for filter.
MOC : CRI/LUBI/KIRLOSKAR
Type : Horizontal Centrifugal
Power Required:1 1Hp
Electrical : 230 V, Single phase , 50 hz
SL.NO. VESSEL MEDIA FILTER Purpose Specifications
3. Flow Rate : 500 lph To remove the total suspended solids, dirt , iron and reduce silt
density index which can foul the membranes.
Make: Alpha
Material of Construction: FRP
Diameter:12
Height : 48”
Testing Pressure :15 kg/cm2 Opening : TopQuantity : 1 No. Valve : ¾”
SL.NO. ACTIVTED CARBON Purpose Specifications
4. Flow Rate : 500 lph To remove the total color, smell, odor, from the water. Make: Alfa/Pentair
Material of Construction: FRP
Diameter: 12
Height: 48”
Testing Pressure: 10 kg/cm2
Opening: Top only Carbon and media vessel merge 2 in one purpose
Quantity : 1 No.
SL.NO. DOSING PUMP Purpose Specifications
5. Flow Rate : 250 lph This pump is used in the treatment of water for proper functioning. The presence of
antiscalant de-lays chemical reaction between calcium,
bicarbonate and magnesium, causing the water to get purified by RO.
MOC: LCM
Capacity : 6 LPH Pressure: 7 Bar
Qty : 1 No.
SL.NO. MICRON FILTER Purpose Specifications Housing Cartridge
6. Flow Rate : 500 lph To remove the fine particles up to 05 microns and reduce
silt density index levels to acceptable level.
Cartridge Filter & Housing MOC of Housing: PP
Length : 20”
Diameter: 6 Quantity : 2 No.
Cartridge MOC : Polypropylene Length:20” Diameter : 4.5” Quantity : 2 No.Micron rating: 05 micron
SL.NO. RO MEMBRANE Purpose Specifications
7. Flow Rate : 500 lph To remove the major part of TDS up to 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow andrecovery. Type: Spiral Wounded
Diameter of Membrane: 4.0 inch
Length of Membranes: 40inch.
No. of Membranes : 2
Salt Rejection per Membrane: 98-99%
System Recovery: 95%
Make of Membranes: by default hii-flow (other brand we can
use on demand by customers. it we be extra chargable. price depend on brand)
SL.NO. HIGH PRESSURE PUMP Purpose Specifications
8. Flow Rate : 500 lph To feed the Reverse Osmosis Membrane at pressure more than the osmotic
pressure taking into consideration flux rate, flow and recovery
MOC : Stainless Steel Type : Vertical Multistage Power Required: 1.5 HP Electrical: 230 V , Single phase, 50 hz Make: CRI/LUBI/KIRLOSKAR
SL.NO. INSTRUMENTATION Purpose Purpose
9. Flow Rate : 500 lph Flow Meter : To measure the online flow of water
High Pressure Switch : protect RO pump from back pressure
Low Pressure Switch : protect RO pump from dry running
Pressure Gauges : For calculate Pressure for each unit in RO system
SL.NO. PLUMBING & FITTINGS Purpose Specifications
10. Flow Rate : 500 lph Valves, pipelines RO module is in upvc Astral. The System will be on common SS base frame
SL.NO. ELECTRICAL PANAL Purpose Specifications
11. Flow Rate : 500 lph A control panel is provided as a safety measure for the pumps & other electrical items . Complete Starters, Overload relays, and single- phase preventer for Pump.
AUTOMATIC